TM 9-2320-365-20-2
2-1316
KNOWN INFO
YES
NO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
11.
If continuity is not present,
J237 positive binding post
is faulty.
POSSIBLE PROBLEMS
Faulty positive 24 vdc
binding post.
Faulty wire 3085L.
Faulty negative 24 vdc
binding post.
Blackout lights OK.
Emergency lights OK.
Fuse OK.
M1079 12/24 vdc power
cable OK.
Wire 1507 OK.
Circuit breaker CB11 OK.
Wire 49 OK.
Is continuity present
across 24 vdc positive (+)
binding post?
Replace positive binding
post (para 16-52).
e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)