16-48. M1079 THERMOSTAT CONNECTOR J245 REPLACEMENT (CONT)
(8) Install dustcap (13) on connector J245 (8) with screw
(14), lockwasher (15), and nut (16).
NOTE
Perform step (9) if heater kit is installed.
(9) Connect connector P245 (17) to connector J245 (8).
(10) Install dust cap (13) on connector J245 (8).
(11) Connect connector J166 (18) to connector P166 (19).
(12) Install raceway cover (20) on raceway (9) with 16
washers (21), lockwashers (22), and screws (23).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-48).
(2) Connect AC power (TM 9-2320-365-10).
(3) Check for proper operation of thermostat (TM 9-2320-
365-10).
(4) Close LH and RH doors (TM 9-2320-365-10).
End of Task.