2-740
TM 9-2320-365-20-1
e61. STOPLIGHTS AND BLACKOUT STOPLIGHTS DO NOT OPERATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
KNOWN INFO
Brakes operate.
Engine starts.
Circuit breaker OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty relay K6.
Faulty stoplight switches.
1.
START
WARNING
Read WARNING
on following page.
Is 12 vdc present on relay
K6 terminal 86?
Go to step 7 of this fault.
YES
NO
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.