TM 9-2320-365-20-1
2-747
CONTINUITY TEST
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
terminal lug TL154.
(3) Connect negative (-) probe of multimeter to
PDP, terminal 85, where relay K6 was
removed, and note reading on multimeter.
(4) If continuity is not present, repair wire 1594
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5) Install relay K6 in PDP.
(6) Install PDP cover (para 16-2).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
terminal lug TL155.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3043
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5) If continuity is present, replace both stoplight
switches (para 11-25).