TM 9-2320-365-20-1
2-989
CONTINUITY TEST
CONTINUITY TEST
(1) Loosen screw in connector PX33.
(2) Disconnect connector PX33 from WTEC II VIM.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector J913-15.
(5) Connect negative (-) probe of multimeter to
connector PX33-E3 and note reading on
multimeter.
(6) If continuity is not present, repair wire 1904
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector PX33-E2.
(3) Connect negative (-) probe of multimeter to
connector J913-14 and note reading on
multimeter.
(4) If continuity is not present, repair wire 2019
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10).
(5) Connect connector PX33 to WTEC II VIM.
(6) Tighten screw in connector PX33.