TM 9-2320-365-20-1
2-1067
CONTINUITY TEST
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector J78-2.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3018
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector J78-4.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3019
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5) If continuity is present, replace radio
(notify Communications Section).
(6) Connect connector J78 to radio.
(7) Install kick panel (para 16-3).