KNOWN INFO
1.
REASON FOR QUESTION
Voltage Test or
STE/ICE-R Test #89
TEST OPTIONS
CAUTION
WARNING
Read WARNING and
CAUTION on
following page.
START
NO
Lighted indicator display OK.
WATER TEMP gage illuminates.
POSSIBLE PROBLEMS
Is 24 vdc present on
connector PX11 pin 3?
Faulty dashboard cable
assembly.
Faulty WATER TEMP gage.
Faulty engine control cable
assembly.
Faulty WATER TEMP gage
sensor.
If 24 vdc is not present, wire
1546 is faulty.
YES
e8. WATER TEMP GAGE DOES NOT OPERATE OR IS INACCURATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
References
TM 9-4910-571-12&P
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Materials/Parts
Wire, Elect, 50 ft (Item 77, Appendix D)
Repair wire 1546 from connector PX11 pin 3
to terminal board TB1 position 61 (para 2-40)
or replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
TM 9-2320-365-20-1