CONTINUITY TEST
(1) Raise cab (TM 9-2320-365-10).
(2) Disconnect connector clamp from WATER
TEMP gage sensor connector, if equipped.
(3) Disconnect connector P41 from WATER
TEMP gage sensor connector.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to connector PX11 pin 4.
(6) Connect negative (-) probe of multimeter
to connector P41 and note reading
on multimeter.
(7) If continuity is not present, go to step 4
of this fault.
(8) If continuity is present, replace WATER
TEMP gage sensor (para 7-42).
(9) Connect connector P41 to WATER TEMP
gage sensor connector.
(10) Connect connector clamp to WATER
TEMP gage sensor connector, if equipped.
(11) Lower cab (TM 9-2320-365-10).
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
NOTE
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CAUTION
Change 1 2-316.3
TM 9-2320-365-20-1