KNOWN INFO
POSSIBLE PROBLEMS
Lighted indicator display OK.
WATER TEMP gage illuminates.
WATER TEMP gage OK.
WATER TEMP gage sensor OK.
Faulty dashboard cable
assembly.
Faulty engine control cable
assembly.
4.
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
If continuity is not present,
wire 33 in dashboard cable
assembly is faulty. If
continuity is present, wire
33 in engine control cable
assembly is faulty.
NO
CAUTION
Read CAUTION
on following page.
Is continuity present
from connector PX11 pin
4 to connector J31 pin 20?
Repair wire 33 from connector P31
socket 20 to connector P41 (para 2-40)
or replace engine control cable
assembly (para 7-72).
YES
Repair wire 33 from connector PX11 pin
4 to connector J31 pin 20 (para 2-40).
or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para7-11).
e8. WATER TEMP GAGE DOES NOT OPERATE OR IS INACCURATE (CONT)
TM 9-2320-365-20-1
2-316.4 Change 1