TM 9-2320-365-20-1
2-464
YES
3.
Is continuity present
between connector J216
terminals A and B?
NO
Other indicator lights
operate.
Hydraulic components
operate normally.
Lighted Indicator
display OK.
Lamps OK.
Dashboard cable
assembly OK.
Auxiliary panel cable
assembly OK.
Faulty PTO.
Faulty PTO cable
assembly.
If continuity is not present,
PTO is faulty. If continuity
is present, wire 3025 is
faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R #91
REASON FOR QUESTION
Notify DS Maintenance.
Repair wire 3025 (para 2-40)
or replace PTO cable
assembly (para 7-77).
e32. PTO INDICATOR DOES NOT OPERATE (CONT)