TM 9-2320-365-20-1
2-471
CONTINUITY TEST
(1) Disconnect connector P210 from connector
J210.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
J210-6.
(4) Connect negative (-) probe of multimeter to
P913-13 and note reading on multimeter.
(5) If continuity is not present, repair wire 2021
(para 2-40) or replace auxiliary panel cable
assembly (all models except M1079 w/o winch)
(para 7-49) or M1079 w/o winch auxiliary panel
cable assembly (para 7-50).
(6) If continuity is present, repair wire 2021
(para 2-40) or replace PTO cable assembly
(para 7-77).
(7) Connect connector J210 to connector P210.
(8) Connect connector P913 to connector J913.
(9) Install personnel heater (para 18-9).