TM 9-2320-365-20-1
2-633
CONTINUITY TEST
CONTINUITY TEST
(1) Remove PDP cover (para 16-2).
(2) Remove relay K13 from PDP.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
PDP, socket 86, where relay K13 was removed.
(5) Connect negative (-) probe of multimeter to
connector PX12-1 and note reading on
multimeter.
(6) If continuity is not present, repair wire 1559
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(7) Connect connector PX12 to warning light
switch.
(8) Install instrument panel assembly (para 7-15).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
PDP, socket 85, where relay K13 was
removed.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3054
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).