Change 1 2-1211
TM 9-2320-365-20-2
CONTINUITY TEST
(1) Disconnect AC power (TM 9-2320-
365-10).
(2) Remove screw and cover from 110 VAC
outlet J230.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to supply pole of 110 VAC receptacle
J230.
(5) Connect negative (-) probe of multimeter
to supply socket of 110 VAC receptacle
J230 and note reading on multimeter.
(6) Connect positive (+) probe of multimeter
to neutral pole of 110 VAC receptacle
J230.
(7) Connect negative (-) probe of multimeter
to neutral socket of 110 VAC receptacle
J230 and note reading on multimeter.
(8) Connect positive (+) probe of multimeter
to ground pole of 110 VAC receptacle
J230.
(9) Connect negative (-) probe of multimeter
to ground socket of 110 VAC receptacle
J230 and note reading on multimeter.
(10) If continuity is not present in steps (5), (7),
and (9), replace 110 VAC receptacle J230
(para 16-53).