NO
TM 9-2320-365-20-2
2-1208 Change 1
e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
AC power connected (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
START
1.
KNOWN INFO
TEST OPTIONS
Operational Test
REASON FOR QUESTION
YES
Go to step 5 of this fault.
This question eliminates
possible problems and
determines where
troubleshooting continues.
Does 110 VAC outlet J235
operate?
POSSIBLE PROBLEMS
110 VAC outlets J231,
J232, J233, and J234 OK.
Faulty circuit breaker CB9.
Faulty wire 701C.
Faulty wire 702C.
Faulty relay K35.
Faulty 110 VAC receptacle
J230.
Faulty wire 1499D.
Faulty wire 3085J.
Faulty wire 3085AC.