TM 9-2320-365-20-2
2-1204 Change 1
e110. M1079 110 VAC OUTLET J231 DOES NOT OPERATE (CONT)
6.
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
KNOWN INFO
POSSIBLE PROBLEMS
110 VAC outlets J230,
J232, J233, and J235 OK.
110 VAC outlet J234 does
not operate.
Circuit breaker CB7 OK.
Faulty wire 701B.
Faulty wire 702B.
Faulty relay K35.
Is continuity present on wire
701B from circuit breaker
CB7 to K35 relay base
terminal 8?
If continuity is not present,
wire 701B is faulty.
YES
Repair or replace wire 701B
(para 2-40).
NO