TM 9-2320-365-20-2
CONTINUITY TEST
(1) Remove instrument panel assembly for access
(para 7-15).
(2) Disconnect connector clamp from speedometer
connector.
(3) Disconnect connector PX8 from speedometer.
(4) Set multimeter to ohms position.
(5) Connect positive (+) probe of multimeter to
connector J111B.
(6) Connect negative (-) probe of multimeter to
connector PX8-4 and note reading on
multimeter.
(7) If continuity is not present, repair wire 1793
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(8) Connect connector PX8 to speedometer.
(9) Connect connector clamp to speedometer
connector.
(10) Install instrument panel assembly (para 7-15).
2-1879