TM 9-2320-365-20-2
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector PX7-9.
(3) Connect negative (-) probe of multimeter to
connector J111D and note reading on multimeter.
(4) If continuity is not present, repair wire 1528
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(5) Connect lighted indicator display to connector
PX7.
(6) Position lighted indicator display in instrument
panel assembly with four screws.
(7) Tighten four screws to 6-10 lb-in. (1 N·m).
2-1891