TM 9-2320-365-20-3
7-8. AUXILIARY PANEL REPLACEMENT (CONT)
b. Installation.
(1) Install decal (1) on auxiliary panel housing (2).
(2) Route auxiliary panel cable assembly (3) in auxiliary
panel housing (2).
(3) Position auxiliary panel housing (2) on heater assembly
(4) with eight screws (5).
(4) Tighten eight screws (5) to 35-44 lb-in. (4-5 N·m).
(5) Position tachometer (6) in auxiliary panel (7) with
retaining ring (8) and two self-locking nuts (9).
(6) Tighten two self-locking nuts (9) to 9 lb-in. (1 N·m).
(7) Install two protective caps (10) on tachometer (6).
(8) Connect connector P901 (11) to tachometer connector
(12).
(9) Connect connector clamp (13) on tachometer connector
(12).
7-34