TM 9-2320-365-20-3
7-66. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE
REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Spare tire lowered (TM 9-2320-365-10).
Cab raised (TM 9-2320-365-10).
Batteries disconnected (para 7-48).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Wrench, Torque, 0-175 lb-ft (Item 57, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Dispenser, Pressure Sensitive Adhesive Tape
(Item 21, Appendix D)
Ties, Cable, Plastic (Item 76, Appendix D)
Lockwasher (Item 89, Appendix G)
Nut, Self-Locking (Item 127, Appendix G)
a. Removal.
(1) Loosen clamp (1) on turbocharger intake hose (2).
(2) Remove turbocharger intake hose (2) from intake air
cleaner boot (3).
(3) Lift terminal cover (4) on terminal lugs TL1 (5), TL36 (6),
and TL37 (7).
NOTE
Remove plastic cable ties as required.
(4) Remove nut (8), lockwasher (9), and terminal lugs TL1
(5), TL36 (6), and TL37 (7) from reverse polarity relay 24
VDC LOAD terminal (10). Discard lockwasher.
7-263