TM 9-2320-365-20-3
7-67. BATTERY TO 100 AMP REVERSE POLARITY RELAY 12 VDC CABLE
REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Spare tire lowered (TM 9-2320-365-10).
Cab raised (TM 9-2320-365-10).
Batteries disconnected (para 7-48).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Lockwasher (Item 89, Appendix G)
a. Removal.
(1) Lift terminal cover (1) on terminal lugs TL61 (2) and
TL47 (3).
NOTE
Remove plastic cable ties as required.
(2) Remove nut (4), lockwasher (5), and terminal lugs TL61
(2) and TL47 (3) from 100 amp reverse polarity relay 12
VDC BAT terminal (6). Discard lockwasher.
NOTE
Note routing of 100 amp reverse polarity
relay 12 vdc cable prior to removal.
(3) Remove battery to 100 amp reverse polarity relay 12 vdc
cable (7) from vehicle.
7-267