TM 9-2320-365-20-3
(13) Deleted.
(14) Deleted.
(15) Deleted.
(16) Deleted.
(17) Position preformed packing (25) and fuel level sending
unit (26) in fuel tank (23) with five screws (27).
(17.1) Tighten five screws (27) to 20-24 lb-in. (2-3 N·m).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away from
open fire and use in a well-ventilated area.
If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately
with soap and water. Failure to comply may
result in injury to personnel.
(18) Apply sealing compound primer to threads of 90-degree
return fitting (28), 90-degree pickup tube fitting (29), and
relief valve (30).
(19) Apply sealing compound to threads of 90-degree return
fitting (28), 90-degree pickup tube fitting (29), and relief
valve (30).
(20) Install 90-degree return fitting (28) in fuel tank (23).
(21) Install 90-degree pickup tube fitting (29) in fuel tank (23).
(22) Install relief valve (30) in fuel tank (23).
Change 1
4-47