TM 9-2320-365-20-4
16-51. M1079 FIELD TELEPHONE BINDING POST/BOX AND CONDUIT REPLACEMENT
(CONT)
(12) Install outlet box (21) on van body wall (22) with two
screws (23).
(13) Install conduit nut (5) on conduit connector (20).
NOTE
PHONE 1 outlet box contains four wires.
PHONE 2 outlet box contains two wires.
Refer to Table 16-2. M1079 Interior Field
Telephone Binding Post Wire Numbers for
details.
(14) Install terminal lugs (24) on wires 425/425A (11) and
424/424A (12).
NOTE
Perform step (15) on PHONE 2 outlet box.
(15) Route wires 1499F (8), 3085G (9), and 702F (10)
through hole in outlet box (21).
NOTE
Perform step (16) on PHONE 1 outlet box.
(16) Route wires 1499D (8), 3085J (9), 702F (10), and 702C
(13) through hole in outlet box (21).
16-324