TM 9-2320-365-20-4
16-52. M1079 24 VDC TERMINAL/BOX AND CONDUIT REPLACEMENT (CONT)
NOTE
Tag wires and connection points prior to
removing.
Right side (J237) 24 vdc POS and GND binding
posts, and left side (J236) 24 vdc NEG binding
post have two wires attached. The remaining
three binding posts have one wire attached.
Refer to Table 16-3. M1079 24 VDC Binding
Post Wire Numbers for details.
Perform steps (2) through (4) on 24 VDC POS,
NEG, and GND binding posts for outlet box
and/or conduit removal.
Table 16-3. M1079 24 VDC Binding Post Wire
Numbers
Binding Post
Identification
Wire Number(s)
J236 24VDC POS
49A
J236 24VDC NEG
3086, 3086
J236 24VDC GND
3085AD
J237 24VDC POS
49, 49A
J237 24VDC NEG
3086
J237 24VDC GND
3085L, 3085AD
(2) Remove nut (4) and terminal lug(s) (5) from binding post
(6).
(3) Remove nut (7), lockwasher (8), washer (9), and nylon
washer (10) from binding post (6).
16-328