TM 9-2320-365-20-4
NOTE
Perform steps (3) through (6) on all 110 vac
outlets.
Tag wires and connection points prior to
disconnecting.
Refer to Table 16-4. M1079 110 VAC Outlet
Box Location and Wire Numbers for details.
(3) Loosen screw (6) in receptacle (5).
(4) Remove neutral wire terminal lug (7) from receptacle (5).
(5) Loosen green screw (8) in receptacle (5).
(6) Remove ground wire and jumper wire terminal lugs (9
and 10) from receptacle (5).
Table 16-4. M1079 110 VAC Outlet Box Location and Wire Numbers
Location
Outlet Number
Outlet Wiring
Supply
Neutral
Ground
Left Front
J233
702D (Bottom)
1499G (Top)
3085W
3085AF (Jumper)
Left Middle
J234
702E (Bottom)
1499E (Top)
3085H
3085AE (Jumper)
Left Rear
J235
702F (Bottom
1499F (Top)
3085G
3085AG (Jumper)
Right Front
J232
702D (Top)
702A (Bottom)
1499B (Top)
3085K
3085AA (Jumper)
Right Middle
J231
702E (Top)
702B (Bottom)
1499C (Top)
3085M
3085AB (Jumper)
Right Rear
J230
702F (Top)
702C (Bottom)
1499D (Top)
3085J
3085AC (Jumper)
16-341