TM 9-2320-365-20-4
NOTE
Perform steps (2) and (3) on circuit breaker
CB10.
(2) Install wire 1508 and 1508A terminal lugs (5 and 6) on
right terminal of circuit breaker CB10 (7) with washer (8)
and screw (9).
(3) Install wire 1507A terminal lug (10) on left terminal of
circuit breaker CB10 (7) with washer (11) and screw
(12).
NOTE
Perform steps (4) and (5) on circuit breaker
CB11.
(4) Install wire 49 (13) on right terminal of circuit breaker
CB11 (1) with washer (14) and screw (15).
(5) Install wire 1507A and 1507 terminal lugs (5 and 16) on
left terminal of circuit breaker CB11 (1) with washer (17)
and screw (18).
(6) Close cover (19) on relay box (2).
(7) Tighten screw (20) on cover (19).