TM 9-2320-365-20-4
16-62. M1079 110 VAC AND 24 VDC RELAY REPLACEMENT (CONT)
b. Installation.
CAUTION
Relay can only be installed one way. Ensure
pins on relay are aligned with sockets on
relay base. Failure to comply may result in
damage to equipment.
(1) Install relay K35 (1) in relay socket (2).
(2) Close cover (3) on relay box (4).
(3) Tighten screw (5) on cover (3).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-48).
(2) Connect AC Power (TM 9-2320-365-10).
(3) Check for proper operation of relay sub system (TM 9-
2320-365-10).
(4) Close LH and RH doors (if desired) (TM 9-2320-365-10).
End of Task.
16-398