TM 9-2320-365-20-4
16-70. M1079 110/208 VAC POWER ENTRY PANEL AND CONDUIT REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Chassis ground lug removed (para 16-69).
110/208 VAC POWER IN/OUT cables removed
(para 16-68).
Field telephone binding posts removed (para 16-
51).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Drill, Portable, Electric (Item 7, Appendix C)
Drill Set, Twist (Item 6, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
Tool Kit, Blind Rivet (Item 43, Appendix C)
Materials/Parts
Sealing Compound (Item 67, Appendix D)
Rivet, Blind (32) (Item 229, Appendix G)
Personnel Required
(2)
a. Removal.
(1) Remove sealing compound from edges of 110/208 vac
power entry panel (1).
(2) Remove wire 3085Y (2) from conduit (3).
(3) Remove wires 424 (4) and 425 (5) from conduit (6).
(4) Loosen conduit nuts (7 and 8) on conduit connectors (9
and 10).
(5) Loosen conduit nuts (11 and 12) on conduit connectors
(13 and 14).
16-468