TM 9-2320-365-20-4
(6) Remove five fittings (18) from winch control valve (2).
(7) Remove five preformed packings (19) from fittings (18).
Discard preformed packings.
b. Installation
(1) Install preformed packing (1) on each of five fittings (2).
(2) Install five fittings (2) in winch control valve (3).
(3) Position two brackets (4) on winch control valve (3) with
four washers (5) and screws (6).
(4) Tighten four screws (6) to 11-13 lb-ft (15-17 N·m).
17-25