TM 9-2320-365-20-5
20-68. 200 AMP TERMINAL BLOCK TO POWER DISTRIBUTION PANEL (PDP) 24 VDC
CABLE REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Batteries disconnected (para 7-48).
PDP cover removed (para 16-2).
Spare tire lowered (TM 9-2320-365-10).
Bottom radiator fan shroud removed (para 6-4).
Cab lowered (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Wrench, Torque, 0-175 lb-ft (Item 57, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Nut, Self-Locking (2) (Item 133, Appendix G)
Lockwasher (Item 89, Appendix G)
Lockwasher (Item 70, Appendix G)
a. Removal.
(1) Remove three screws (1) and washers (2) from PDP (3).
(2) Remove three screws (4) from PDP (3).
(3) Lift PDP (3) outward to gain access.
NOTE
Remove plastic cable ties as required.
(4) Remove screw (5), lockwasher (6), terminal lug TL42 (7),
and four terminal lugs (8) from PDP (3). Discard
lockwasher.
(5) Position four terminal lugs (8) on PDP (3) with screw (5).
20-401