TM 9-2320-365-20-523-7. WET TANK REPLACEMENT (CONT)(12) Remove two 90-degree fittings (12) from street tee fitting(10).b. Installation.WARNINGAdhesives, solvents, and sealing com-pounds can burn easily, can give offharmful vapors, and are harmful to skinand clothing. Keep away from open fireand use in a well-ventilated area. Ifadhesive, solvent, or sealing compoundgets on skin or clothing, washimmediately with soap and water. Failureto comply may result in injury topersonnel.(1) Apply antiseize compound to threads of drain valve (1).(2) Install drain valve (1) in wet tank (2).23-32.2 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business