TM 9-2320-365-20-5
Section II. MAINTENANCE PROCEDURES
24-2. AIR FILTER RESTRICTION GAUGE REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Batteries disconnected (para 7-48).
Instrument panel assembly removed for access (para
7-15).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
a. Removal.
(1) Disconnect vacuum hose (1) from AIR FILTER
RESTRICTION GAUGE (2).
(2) Remove two screws (3) and AIR FILTER RESTRICTION
GAUGE faceplate (4) from instrument panel assembly
(5).
(3) Remove AIR FILTER RESTRICTION GAUGE (2) from
instrument panel assembly (5).
b. Installation.
(1) Position AIR FILTER RESTRICTION GAUGE (2) in
instrument panel assembly (5).
(2) Install AIR FILTER RESTRICTION GAUGE faceplate (4)
on instrument panel assembly (5) with two screws (3).
(3) Connect vacuum hose (1) to AIR FILTER RESTRICTION
GAUGE (2).
c. Follow-On Maintenance.
(1) Install instrument panel assembly (para 7-15).
(2) Connect batteries (para 7-48).
(3) Start engine (TM 9-2320-365-10).
(4) Check operation of AIR FILTER RESTRICTION GAUGE.
(5) Shut down engine (TM 9-2320-365-10).
End of Task.
24-2