TM 9-2320-365-20-2
2-1210 Change 1
e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT)
2.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
110 VAC outlets J231,
J232, J233, and J234 OK.
110 VAC outlet J235 OK.
Circuit breaker CB9 OK.
Wire 701C OK.
Wire 702C OK.
Relay K35 OK.
Faulty 110 VAC receptacle
J230.
Faulty wire 1499D.
Faulty wire 3085J.
Faulty wire 3085AC.
Is continuity present across
110 VAC receptacle J230?
If continuity is not present,
110 VAC receptacle J230
is faulty.
YES
Replace 110 VAC receptacle
J230 (para 16-53).
NO