CONTINUITY TEST
(1) Remove instrument panel assembly for
access (para 7-15).
(2) Disconnect connector J43 from connector
P43.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector P43 pin 2.
(5) Connect negative (-) probe of multimeter to
connector P84 socket B and note reading on
multimeter.
(6) If continuity is not present, repair wire 1790
from connector P43 pin 2 to connector
P84 socket B (para 2-40) or replace start
and charging cable assembly (para 7-82).
(7) Connect connector P84 to air pressure
switch.
Change 1 2-909
TM 9-2320-365-20-1
CONTINUITY TEST
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CAUTION
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector P84 socket A.
(3) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3032
from connector P84 socket A to terminal lug
TL85 (para 2-40) or replace start and
charging cable assembly (para 7-82).