CONTINUITY TEST
(1) Disconnect connector P110 from CTIS ECU.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
connector P111 pin E.
(4) Connect negative (-) probe of multimeter to
connector P110 socket H and note reading
on multimeter.
(5) If continuity is not present, replace CTIS
cable assembly (para 7-53).
Change 1 2-913
TM 9-2320-365-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CONTINUITY TEST
(1) Remove circuit breaker CB40 from PDP.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
connector J111 socket E.
(4) Connect negative (-) probe of multimeter to
circuit breaker CB40 socket 7 and note
reading on multimeter.
(5) If continuity is not present, repair wire 1911
from connector J111 socket E to circuit
breaker CB40 socket 7 (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(6) Install circuit breaker CB40 on PDP.