Change 1 2-917
TM 9-2320-365-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CONTINUITY TEST
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Disconnect connector P112 from pneumatic
controller connector.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
connector P111 pin A.
(4) Connect negative (-) probe of multimeter to
connector P112 socket A and note reading
on multimeter.
(5) If continuity is not present, replace CTIS
cable assembly (para 7-53).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P111 pin A.
(3) Connect negative (-) probe of multimeter to
connector P112 socket B and note reading
on multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).