CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110 socket P.
(3) Connect negative (-) probe of multimeter to
terminal lug TL50 and note reading on
multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).
(5) Connect connector P110 to CTIS ECU.
Change 1 2-918.3
TM 9-2320-365-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110 socket C.
(3) Connect negative (-) probe of multimeter to
connector P112 socket E and note reading
on multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).