CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110 socket B.
(3) Connect negative (-) probe of multimeter to
connector P112 socket F and note reading
on multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).
(5) Connect connector P111 to connector
J111.
Change 1 2-918.1
TM 9-2320-365-20-1
CAUTION
CONTINUITY TEST
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110 socket R.
(3) Connect negative (-) probe of multimeter to
connector P112 socket D and note reading
on multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).