RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
pneumatic controller connector pin F.
(3) Connect negative (-) probe of multimeter to
pneumatic controller connector pin A and
note reading on multimeter.
(4) If continuity is not present at 30-80 ohms
resistance, replace manifold valve
assembly (para 12-7).
Change 1 2-918.5
TM 9-2320-365-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
pneumatic controller connector pin D.
(3) Connect negative (-) probe of multimeter to
pneumatic controller connector pin B and
note reading on multimeter.
(4) If continuity is not present at 30-80 ohms
resistance, replace manifold valve
assembly (para 12-7).