CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Remove kick panel (para 16-3).
(2) Disconnect connector P111 from connector
J111.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector J43 socket 2.
(5) Connect negative (-) probe of multimeter to
connector J111 socket F and note reading
on multimeter.
(6) If continuity is not present, repair wire 1790
from connector J43 socket 2 to connector
J111 socket F (para 2-40) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable assembly
(para 7-11).
(7) Connect connector P43 to connector J43.
(8) Install instrument panel assembly (para
7-15).
(1) Remove three screws and washers from
PDP.
(2) Remove three screws from PDP.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to connector J111 socket A.
(5) Lift PDP out to gain access.
(6) Connect negative (-) probe of multimeter
to terminal board TB2 position 35 and note
reading on multimeter.
(7) If continuity is not present, repair wire 3031
from connector J111 socket A to terminal
board TB2 position 35 (para 2-40) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable assembly
(para 7-11).
(8) Install PDP on dashboard with three screws.
(9) Install three washers and screws in PDP.
CONTINUITY TEST
Change 1 2-911