TM 9-2320-365-20-1
2-944
NO
YES
3.
NO
YES
4.
Is 24 vdc present on
connector P903 terminal 3?
If 24 vdc is not present,
wire 1924 is faulty.
Faulty WINCH IN/OUT
switch.
If continuity is not present,
WINCH IN/OUT switch is
faulty.
KNOWN INFO
Circuit breaker OK.
PTO OK.
Winch power switch OK.
POSSIBLE PROBLEMS
Faulty auxiliary panel
cable assembly.
Faulty WINCH IN/OUT
switch.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
KNOWN INFO
Circuit breaker OK.
PTO OK.
Winch power switch OK.
Auxiliary panel cable
assembly OK.
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R #91
REASON FOR QUESTION
Fault not corrected.
Notify DS Maintenance.
Is continuity present
between WINCH IN/OUT
switch terminal 3 and
terminal 1?
Repair wire 1924 (para 2-40)
or replace auxiliary panel
cable assembly (all models
except M1079 w/o winch)
(para 7-49).
Replace WINCH IN/OUT
switch (para 7-18).
e85. 11K SELF-RECOVERY WINCH DOES NOT REEL IN OR PAY OUT (CONT)