TM 9-2320-365-20-1
2-949
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
winch in solenoid L4 terminal 2.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3069
(para 2-40) or replace winch control valve
cable assembly (para 7-85).
(5) If continuity is present, replace winch control
valve assembly (para 17-6).
(6) Connect winch in solenoid L4 connector on
solenoid L4 and tighten screw.