TM 9-2320-365-20-1
2-969
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector J215-1.
(3) Connect negative (-) probe of multimeter to
winch out solenoid L5 connector terminal 1
and note reading on multimeter.
(4) If continuity is not present, repair wire 2008
(para 2-40) or replace winch control valve
cable assembly (para 7-85).
(5) If continuity is present, notify DS Maintenance.
(6) Connect connector P215 to connector J215.
(7) Connect winch out solenoid L5 connector to
solenoid L5 and tighten screw.