TM 9-2320-365-20-1
2-965
CONTINUITY TEST
(1) Remove kick panel (para 16-3).
(2) Disconnect connector P210 from connector J210.
(3) Set
multimeter
to ohms.
(4) Connect positive (+) probe of
multimeter
to
connector P903-7.
(5) Connect negative (-) probe of
multimeter
to
connector P210-8 and note reading on
multimeter.
(6) If
continuity
is not present, repair wire 2008
(para 2-40) or replace auxiliary panel cable
assembly (all models except M1079 w/o winch
(para 7-49).
(7) Connect connector P903 to WINCH IN/OUT
switch.
(8) Position auxiliary panel on
auxiliary panel housing with six screws.
(9) Tighten six screws to 24 lb-in. (3 N·m).