TM 9-2320-365-20-1
2-329
RESISTANCE TEST
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector PX6-4.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If 22 to 26 ohms resistance is not present,
go to step 3 of this fault.
(5) If 22 to 26 ohms resistance is present,
replace engine oil pressure gage (para 7-14).
(1) Raise cab (TM 9-2320-365-10).
(2) Disconnect connector clamp from connector
J32.
(3) Disconnect connector P32 from connector
J32.
(4) Connect positive (+) probe of multimeter to
connector J32-2.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) If 22 to 26 ohms resistance is not present,
go to step 4 of this fault.
(7) If 22 to 26 ohms resistance is present,
replace oil pressure transducer (para 7-41).
(8) Connect connector P32 to connector J32.
(9) Connect connector clamp on connector J32.
(10) Lower cab (TM 9-2320-365-10).