e13. VOLTS GAGE DOES NOT OPERATE OR IS INACCURATE
Personnel Required
(2)
References
TM 9-4910-571-12&P
START
Is 24 VDC present on
connector PX10 pin 3?
WARNING
CAUTION
Read WARNING and
CAUTION on
following page.
1.
Go to step 3 of this fault.
NO
YES
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
KNOWN INFO
Circuit breaker CB77 OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty VOLTS gage.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
TM 9-2320-365-20-1
2-346 Change 1
NOTE
Perform Electrical System Troubleshooting
e1. Circuit Breaker Does Not Operate on
circuit breaker CB77 prior to beginning
this task.