CONTINUITY TEST
VOLTAGE TEST
(1) Set multimeter to volts DC.
(2) Connect positive (+) probe of multimeter to
PDP terminal 30, where relay K7 was
removed.
(3) Connect negative (-) probe of multimeter to
ground.
(4) Position main light switch to SER DRIVE
(TM 9-2320-365-10) and note reading on
multimeter.
(5) If 12 VDC is not present, Repair wire 1416
from PDP relay K7 terminal 30 to circuit
breaker CB78 (para 2-40) or replace WTEC II
dashboard cable assembly (para 7-10) or
WTEC III dashboard cable assembly (para
7-11).
(6) Position main light switch to OFF (TM 9-
2320-365-10).
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
WARNING
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
PDP terminal 85, where relay K7 was
removed.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3002
from PDP relay K7 terminal 85 to terminal
board TB2 position 74 (para 2-40) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable assembly
(para 7-11).
Change 1 2-517
TM 9-2320-365-20-1