CONTINUITY TEST
CONTINUITY TEST
(1) Remove relay K8 from PDP.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
PDP terminal 87, where relay K7 was
removed.
(4) Connect negative (-) probe of multimeter to
PDP terminal 30, where relay K8 was
removed and note reading on multimeter.
(5) If continuity is not present, repair wire 1417
from PDP relay K7 terminal 87 to PDP relay
K8 terminal 30 (para 2-40) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable assembly
(para 7-11).
(6) Install relay K7 in PDP.
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
relay K8 terminal 87A.
(3) Connect negative (-) probe of multimeter to
relay K8 terminal 30 and note reading on
multimeter.
(4) If continuity is not present, replace relay
K8 (para 7-9).
(5) If continuity is present, replace relay K7
(para 7-9).
(6) Install relay K8 in PDP.
(7) Install PDP cover (para 16-2).
TM 9-2320-365-20-1
Change 1 2-518.1