TM 9-2320-365-20-2
2-2093
CONTINUITY TEST
CONTINUITY TEST
(1) Open cover on LMHC control box.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
NATO plug positive (+) terminal.
(4) Connect negative (-) probe of multimeter to
LMHC control box circuit breaker supply post
and note reading on multimeter.
(5) If continuity is not present, replace wire 170
(para 20-63).
(1) Disconnect LMHC control box power cable
from LMHC control box connector.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
NATO plug negative (-) terminal.
(4) Connect negative (-) probe of multimeter to
LMHC control box connector pin B and note
reading on multimeter.
(5) If continuity is not present, replace wire 150
(para 20-63).
(6) Install cover and retainer on NATO plug with
eight screws.