TM 9-2320-365-20-2
2-2088
1.
YES
NO
Engine starts.
POSSIBLE PROBLEMS
START
WARNING
Read WARNING
on following page.
KNOWN INFO
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
Faulty NATO power cable.
Faulty NATO plug.
Faulty wire 150.
Faulty circuit breaker.
Faulty wire 170.
Faulty wire 592.
Faulty power cable.
Faulty power harness.
Faulty out solenoid.
Faulty in solenoid.
Faulty LMHC winch
assembly.
Faulty winch cable.
u19. LIGHT MATERIAL HANDLING CRANE (LMHC) DOES NOT OPERATE
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
Replace NATO power
cable (para 7-63).
Is 24 vdc present
across NATO power
receptacle?
If 24 vdc is not present,
NATO power cable is
faulty.