TM 9-2320-365-20-2
2-1310
e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)
KNOWN INFO
YES
NO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
If continuity is not present,
wire 1507 is faulty.
8.
Is continuity present
from connector J173
pin G and H to circuit
breaker CB11 wire
1507?
POSSIBLE PROBLEMS
Faulty wire 1507.
Faulty circuit breaker
CB11.
Faulty wire 49.
Faulty positive 24 vdc
binding post.
Faulty wire 3085L.
Faulty negative 24 vdc
binding post.
Blackout lights OK.
Emergency lights OK.
Fuse OK.
M1079 12/24 vdc power
cable OK.
Repair or replace wire 1507
(para 2-40).